Performance

The Power of Vacuum

Performance Overview

Enthermal™ glazing stands out through unmatched technical performance, combining energy efficiency, durability, and a slim-profile design.

R18

Center-of-glass insulation

77

Condensation resistance factor

0.25

Solar heat gain coefficient

33+

Sound transmission rating

8 mm

Slim-profile design

20 ans

Product warranty

4.6 kg/ft²

Embodied carbon emissions

100 %

Recyclable product

Industry Standard Testing and Accelerated Durability

  • To ensure long-lasting and consistent performance, Enthermal™ has undergone a comprehensive series of industry-standard tests and accelerated durability protocols.

    Because Enthermal™ VIG units successfully passed all standard testing requirements while significantly exceeding industry benchmarks, LuxWall developed an accelerated aging protocol to ensure Enthermal™ products will perform reliably in the built environment for decades — even under the harshest weather conditions.

    The accelerated testing program, which thoroughly evaluates product design, raw materials, manufacturing processes, and overall VIG unit performance, was also completed successfully.

Industry Standard Testing

ASTM 2188 / 2189 / 2190

Insulated Glass Unit (IGU) Certification

ASTM E2264

Thermal cycling resistance

ASTM E330

Static air pressure resistance (wind load)

AAMA 910 — 25,000 Cycles

Mechanical durability testing (Door Slam Cycles)

ASTM B117

Salt spray exposure testing (corrosion resistance)

AAMA 1503

Thermal and condensation resistance

ASTM C518

U-factor validation

Accelerated Durability Testing (LuxWall)

-60 °C à +130 °C

Accelerated thermal cycling

+85 °C with 85% Humidity

Extended extreme humidity testing

± 90 °C

Asymmetrical thermal shock testing

-30 °C to +71 °C with 98% Humidity

Intensive climate stress testing

Accelerated UV Exposure (up to 32x)

Simulation of years of solar exposure

Immersion at 65 °C / 10 Days / pH 3.5 to 10

Chemical resistance and material endurance testing

Laboratory Testing

  • A local certification complements the full range of validations already achieved and confirms the product’s compliance with applicable industry standards. It supports performance analysis and technical comparisons within a measurable and repeatable framework.

    Testing performed according to the NFRC 102 standard ensures precise thermal performance characterization based on a protocol recognized throughout North America. Results obtained from an accredited independent laboratory provide a reliable foundation for energy calculations and simulation models.